| AVAILABLE OPTIONS (SOME OPTIONS NOT APPLICABLE TO ALL MODELS) Many other features/options available, if it’s possible, we can do it |
|
| A1 | Water Cooled Condenser |
| COLORS | |
| Custom Colors available for OEM customers | |
| CONTROLS | |
| E1 | Control Package e1 include Touch Screen Control |
| -Level Low – Mute – Normal screen GREEN/RED on fault | |
| -Low Flow | |
| -Temperature Alarm | |
| -Cooling on LED | |
| -Relay contact open on fault (NC dry), via DB9-F, pins 1 & 9 | |
| -Remote start/stop on DB9-F, pins 3 & 7 | |
| -Auto restart when in REMOTE mode on power loss | |
| -RUN on FAULT version available | |
| E2 | RS-232 Interface with temp controller VIA USB/LAN *& PC based software |
| E3 | RS-484 Interface with temp controller with PC based software |
| E4 | Analog remote control 1-5, 0-5 or 0-10VDC of temp controller |
| E5 | Devicenet communication with temp controller |
| E6 | E1 with an additional input, i.e. pressure switch, etc |
| EM | Energy meter |
| RV | Return temperature display option, not available for all units |
| HM | Hour meter |
| POWER | |
| C1 | 100-120VAC 50/60 Hz |
| C2 | 200-230VAC 50/60 Hz, Single phase |
| C3 | 200V-240V50 Hz, Single phase |
| C5 | 200V-20V50/60 Hz, Three phase |
| C6 | 440-480VAC, Three phase |
| C7 | 380-460VAC, Three phase, 50 Hz |
| FLUID MAINTENANCE | |
| G1 | DI (500kΩ-2MΩ) resistivity status LED, filter & plumbing; includes replaceable DI Cartridge |
| G2 | Resistivity meter (0-20MΩ) an add-on w/G1 option |
| G3 | 80C DI (50kΩ – 2MΩ) resistivity status LED, filter & plumbing; includes replaceable DI Cartridge |
| G4 | G1 + G2 solenoid control of resistivity level |
| F1 | Stainless steel/plastic plumbing (1/2″) (up to 10 GPM) |
| H1 | Particle Filter (5 microns) 1/2″ NPT |
| H2 | Particle Filter (30 microns) 1/2″ NPT |
| H4 | Particle Filter (30 microns) 3/4″ NPT |
| H5 | Particle Filter SS housing (30 microns) 3/4″ port |
| H6 | Particle Filter (5 microns) 80C compatible 1/2″ NPT |
| H7 | Particle Filter (30 microns) 80C compatible 1/2″ NPT |
| H8 | Particle Filter (30 microns) 20 GPM compatible 3/4″ NPT |
| FLUID MEASUREMENT & CONTROL | |
| B1/2 | 2nd supply & return loop with flow switch, 1/2″ NPT |
| B3/4 | 2nd supply & return loop with flow switch, 3/4″ NPT |
| FB1/2 | Anti flood back kit 1/2″ |
| FB3/4 | Anti flood back kit 3/4″ |
| FB1/2SS | SS Anti flood back kit 1/2″ |
| FB3./4SS | SSAnti flood back kit 3/4″ |
| FBS | Solenoid controlled anti-flood back system |
| J0 | Flow Meter with flow control (0.2-1.5 GPM) 1/2″ NPT |
| J1 | Flow Meter with flow control (0.5-2.5 GPM) 1/2″ NPT |
| J3 | Flow Meter with flow control (20 GPM) 1″ NPT |
| J4 | Flow Meter with flow control (40 GPM) 1″ or 2″ NPT |
| J5 | Flow Meter with flow control (1040 GPM) 1.5″ or 2″ NPT |
| J6 | 0-5 GPM digital flow display with flow control adjustment |
| J7 | 0-10 GPM digital flow display with flow control adjustment |
| J8 | 1.5-19 GPM digital flow display with flow control adjustment |
| J9 | 4-40 GPM digital flow display with flow control adjustment |
| K5 | Heater 500 watts Stainless sheath type in reservoir |
| K10 | Heater 1000 watts Stainless sheath type in reservoir |
| K20 | Heater 2000 watts Stainless sheath type |
| K50 | Heater 5000 watts Stainless sheath type |
| KS | Custom Heater |
| KC | Heater with separate control |
| L1 | Auto fill with redundant safety 1/4″ ports for supply & return |
| PD | Pulsation dampener on supply line Brass |
| PR | Pressure Regulating valve, for limiting supply pressure |
| PUMPS | |
| PS | Special or custom pump |
| P2 | Positive displacement pump-Brass 4.0 GPM |
| P3 | Positive displacement pump-SS-2.2 GPM |
| P4 | Positive displacement pump-SS-4.0 GPM |
| P5 | Turbine type pump BRASS 5 GPM @ 60PSI |
| P6 | Turbine type pump BRASS 10 GPM @ 60PSI |
| P7 | Turbine type pump BRASS 15 GPM @ 60PSI |
| P8 | Turbine type pump SS 15 GPM @ 60PSI |
| P9 | Turbine type pump BRASS 20 GPM @ 60PSI |
| P10 | Turbine type pump SS 20 GPM @ 60PSI |
| P11 | Centrifugal type pump SS 10 GPM @40 PSI |
| P12 | Centrifugal type pump SS 15 GPM @40 PSI |
| P13 | Centrifugal type pump SS 20 GPM @40 PSI |
| P14 | Magnetically coupled SS pump 2 GPM @ 80PSI |
| P15 | Magnetically coupled SS pump 4 GPM @ 80PSI |
| P16 | Centrifugal type pump SS 30 GPM @ 60 PSI |
| HOSE KITS | |
| HK1 | 1/2″ id opaque hose push-lok type 10′, 25′ or 50′ |
| HK2 | 3/4″ id opaque hose push-lok type 10′, 25′ or 50′ |
| HK3 | 1/2″ id opaque hose push-lok type 10′, 25′ or 50′ with 3/8″ wall thermal insulation |
| HK4 | 3/4″ id opaque hose push-lok type 10′, 25′ or 50′ with 3/8″ wall thermal insulation |
| HK5 | 1/2″ id opaque hose push-lok type 10′, 25′ or 50′ with 3/4″ wall thermal insulation |
| HK6 | 3/4″ id opaque hose push-lok type 10′, 25′ or 50′ with 3/4″ wall thermal insulation |
| Order hose as follows, HO1-25m would call out 25′ length, all hoses come with swivel fittings | |
| FLUIDS | |
| EG | ETHYLENE GLYCOL INDUSTRIAL GRADE 1 GAL |
| EG50/50 | ETHYLENE GLYCOL /WATER 50% MIXTURE INDUSTRIAL GRADE 1 GAL |
| EG60/40 | ETHYLENE GLYCOL /WATER 60/40% MIXTURE INDUSTRIAL GRADE 1 GAL |
| HT110 | GALDEN FLUORINATED FLUID FOR UP TO 100°C |
| HT135 | GALDEN FLUORINATED FLUID FOR UP TO 135°C |
| HT200 | GALDEN FLUORINATED FLUID FOR UP TO 200°C |
| HT270 | GALDEN FLUORINATED FLUID FOR UP TO 270°C |
| Other fluids available please ask your engineer or sales associate | |
| REMOTE | |
| RC | 25″ NULL MODEN DB9 M TO F CABLE |
| USB1 | USB TO SERIAL (RS-232) CONVERTER |
| CNVRT | RS232 TO RS485 PORT POWERED CONVERTER |
| OTHER | |
| OD | NEMA 4x Electrical enclosure & weather proofing measures |
| OL | Open Loop Plumbing configuration (for non-pressurized return) |
| -2 | Dual channel system |
| -3 | Three channel system |
| -4 | Four channel system |
| -5 | Five channel system |
| -6 | Six channel system |
| 19R | Rack mount frame sliding mount rails |
| SR | Seismic restraints with adjustable height for easy installation |
| If you don’t see what you are looking for, please ask the sales representative. There are many other available features and pump options. | |
| Not all options are available for all models, please consult BV Thermal Systems engineering or sales department for applicability. | |